Cleanroom Classification: ISO 14644 vs Grade A–D Explained

Quick answer: Cleanrooms are classified by how many airborne particles they allow per cubic metre. ISO 14644-1 uses ISO Classes 1–9 (ISO 5 allows 3,520 particles ≥0.5 µm per m³). Pharma uses Grades A–D under Schedule M and EU GMP: Grade A matches ISO 5, Grade B is ISO 5 at rest, Grade C is ISO 7 at rest, and Grade D is ISO 8 at rest. The stricter the class, the more often and more carefully it must be cleaned.

Cleanroom Classification: ISO 14644 vs Grade A–D Explained

What is cleanroom classification?

A cleanroom’s class is the maximum number of airborne particles it may contain, counted per cubic metre of air at set particle sizes. Lower class numbers and earlier grade letters mean cleaner air.

Two systems matter in India. ISO 14644-1 is the international standard used across industries, from electronics to hospitals. Grades A–D are the pharma system used in India’s Revised Schedule M and EU GMP for sterile medicine manufacturing. Most pharma cleanrooms are described in both.

What are the ISO 14644-1 cleanroom classes?

ISO 14644-1 defines nine classes. Each step up allows roughly ten times more particles. ISO 5, 7 and 8 are the classes most used in pharma and electronics.

ISO class

Max particles ≥0.5 µm per m³

Max particles ≥5 µm per m³

Old FED-STD-209E name

Typical use

ISO 3

35

–

Class 1

Semiconductor lithography

ISO 4

352

–

Class 10

Semiconductor and advanced electronics

ISO 5

3,520

–

Class 100

Aseptic filling zones, laminar-flow hoods

ISO 6

35,200

293

Class 1,000

Medical devices, electronics assembly

ISO 7

352,000

2,930

Class 10,000

Pharma background areas, hospital pharmacy

ISO 8

3,520,000

29,300

Class 100,000

Gowning rooms, oral solid dosage, packaging

ISO 9

35,200,000

293,000

Room air

In-operation only; general controlled areas

Limits from ISO 14644-1:2015 Table 1; old FED-STD-209E names from Berkshire. ISO 1 and 2 are not counted at 0.5 µm. “–” means the standard does not classify at that size for that class.

The old US standard FED-STD-209E was withdrawn in 2001, but people still say “Class 100” or “Class 10,000”. Class 100 means ISO 5, Class 10,000 means ISO 7, and Class 100,000 means ISO 8.

What are pharma cleanroom Grades A, B, C and D?

India’s Revised Schedule M classifies sterile manufacturing clean areas into four grades, matching EU GMP. Each grade has limits for two states: at rest (equipment running, no people) and in operation (normal staffing).

Grade

What it’s used for

Particles ≥0.5 µm/m³ at rest

Particles ≥0.5 µm/m³ in operation

ISO equivalent (at rest / in operation)

Air microbes, in operation (CFU/m³)

A

High-risk operations: filling, aseptic connections

3,520

3,520

ISO 5 / ISO 5

<1

B

Background for Grade A in aseptic work

3,520

352,000

ISO 5 / ISO 7

10

C

Less critical sterile steps (e.g. solution preparation)

352,000

3,520,000

ISO 7 / ISO 8

100

D

Less critical steps, product not directly exposed

3,520,000

Not defined

ISO 8 / –

200

Particle limits from Revised Schedule M, Part II, Table 1; microbial limits are the recommended averages in the same notification, given for information. ISO equivalents follow from matching the 0.5 µm limits to ISO 14644-1.

The key point for cleaning: Grade B and C rooms are allowed to get dirtier when people are working in them, which is why cleaning, gowning and staff discipline matter most during operation.

How does cleaning change by cleanroom grade?

The stricter the grade, the more often you clean, the cleaner your agents and tools must be, and the more the cleaners must wear. Garment rules below come from Schedule M Part II, para 7.8; frequencies reflect typical practice and should follow your own validated SOPs.

 

Grade A / ISO 5

Grade B / ISO 5–7

Grade C / ISO 7–8

Grade D / ISO 8

Typical cleaning frequency

Before and after each session, and between batches

Every shift; walls weekly

Daily; walls and ceilings weekly to monthly

Daily floors; walls and ceilings monthly

Disinfectants

Sterile agents only; rotate with a sporicide

Sterile agents only; rotate with a sporicide

Rotation of two or more agents plus a periodic sporicide

Rotation plus a periodic sporicide

Cleaner’s clothing (Schedule M)

Full headgear, one-piece suit, face mask, sterile powder-free gloves, sterilised footwear

Same as Grade A

One-piece jumpsuit with high neck and wrist gathers, shoes or overshoes

Hair and beard covered, protective clothing, suitable shoes or overshoes

Tools

Sterile, single-use or autoclaved wipes and mops

Sterile wipes, dedicated mop systems

Grade-dedicated, colour-coded mops and buckets

Grade-dedicated, colour-coded tools

Method

Unidirectional strokes, top to bottom, clean to dirty

Same, with overlapping strokes

Two- or three-bucket mopping, top to bottom

Two-bucket mopping, top to bottom

Schedule M also requires disinfectants to be monitored for microbial contamination, and those used in Grade A and B to be sterile before use (Part II, para 3.2).

Which industries use which cleanroom class?

Industry

Typical classes

Examples in India

Sterile pharma (injectables, eye drops)

Grade A–D (ISO 5–8)

Formulation plants in Hyderabad, Goa, Ahmedabad and Baddi

Oral solid dosage (tablets, capsules)

Grade D / ISO 8 and controlled areas

Most generic drug plants

Biotech and biologics

Grade A–C (ISO 5–7)

Bengaluru and Genome Valley, Hyderabad

Semiconductors and electronics

ISO 3–7

New fabs and assembly units in Karnataka, Telangana and Gujarat

Medical devices

ISO 7–8

Device makers needing sterile packaging

Hospital pharmacy and IVF labs

ISO 5–7

Compounding rooms and IVF labs

Food, flavours and nutraceuticals

ISO 8 and controlled areas

High-care packing zones

Space and defence

ISO 5–8

Satellite and instrument assembly

How PinkClean cleans classified cleanrooms

PinkClean is a member of the Contamination Control Society of India (CCSI) and an ISO-certified cleaning company for pharma, biotech, electronics and industrial facilities in Bangalore, Hyderabad, Goa and Kochi.

Our clean room cleaning teams match the method to the grade:

  • Gowned to grade, following your gowning SOP and Schedule M clothing rules
  • Grade-dedicated, colour-coded tools, never moved from a lower grade to a higher one
  • Your disinfectant rotation and sporicide schedule, at the right dilution and contact time
  • Signed cleaning logs that support your environmental monitoring and audits

Our industrial projects include ISRO SHAR, RenewSys, Prova Flavours and MANN+HUMMEL. For the full compliance picture, read our Revised Schedule M cleaning checklist.

Frequently asked questions

What is an ISO 5 cleanroom?

An ISO 5 cleanroom allows no more than 3,520 particles of 0.5 µm or larger per cubic metre of air. It is the old “Class 100” and matches pharma Grade A.

What is the difference between ISO 7 and ISO 8 cleanrooms?

ISO 7 allows up to 352,000 particles ≥0.5 µm per m³, while ISO 8 allows up to 3,520,000, ten times more. ISO 7 was called Class 10,000 and ISO 8 was called Class 100,000.

What is a Class 100 cleanroom?

Class 100 is the old FED-STD-209E name for an ISO 5 cleanroom: at most 100 particles ≥0.5 µm per cubic foot, or 3,520 per cubic metre.

What are Grade A, B, C and D cleanrooms?

They are the pharma cleanroom grades in India’s Schedule M and EU GMP. Grade A is for high-risk work like filling, Grade B is its background, and Grades C and D are for less critical steps.

Is Grade A the same as ISO 5?

Yes. Grade A must meet ISO 5 particle limits both at rest and in operation. Grade B meets ISO 5 at rest but only ISO 7 in operation.

How often should a cleanroom be cleaned?

It depends on the grade and your validated SOPs. Grade A and B areas are typically cleaned every session or shift, Grade C and D daily, with walls and ceilings weekly to monthly and a periodic sporicidal round.

What disinfectants are used in pharma cleanrooms?

Schedule M requires more than one type of disinfectant in sterile clean areas, including a sporicidal agent, and disinfectants used in Grade A and B must be sterile.

Need your classified areas cleaned to grade?

PinkClean, a CCSI member and ISO-certified company, cleans Grade A–D and ISO 5–8 cleanrooms for pharma, biotech and electronics plants in Bangalore, Hyderabad, Goa and Kochi. Book a free site assessment and we’ll map a cleaning plan to each room’s grade.

📞 Bangalore: 96065 10235 · Mangalore: 91084 44692 · 🌐 pinkcleanindia.com

Sources

BOOK YOUR CLEANING
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.