Quick answer: Cleanrooms are classified by how many airborne particles they allow per cubic metre. ISO 14644-1 uses ISO Classes 1–9 (ISO 5 allows 3,520 particles ≥0.5 µm per m³). Pharma uses Grades A–D under Schedule M and EU GMP: Grade A matches ISO 5, Grade B is ISO 5 at rest, Grade C is ISO 7 at rest, and Grade D is ISO 8 at rest. The stricter the class, the more often and more carefully it must be cleaned.
A cleanroom’s class is the maximum number of airborne particles it may contain, counted per cubic metre of air at set particle sizes. Lower class numbers and earlier grade letters mean cleaner air.
Two systems matter in India. ISO 14644-1 is the international standard used across industries, from electronics to hospitals. Grades A–D are the pharma system used in India’s Revised Schedule M and EU GMP for sterile medicine manufacturing. Most pharma cleanrooms are described in both.
ISO 14644-1 defines nine classes. Each step up allows roughly ten times more particles. ISO 5, 7 and 8 are the classes most used in pharma and electronics.
ISO class | Max particles ≥0.5 µm per m³ | Max particles ≥5 µm per m³ | Old FED-STD-209E name | Typical use |
|---|---|---|---|---|
ISO 3 | 35 | – | Class 1 | Semiconductor lithography |
ISO 4 | 352 | – | Class 10 | Semiconductor and advanced electronics |
ISO 5 | 3,520 | – | Class 100 | Aseptic filling zones, laminar-flow hoods |
ISO 6 | 35,200 | 293 | Class 1,000 | Medical devices, electronics assembly |
ISO 7 | 352,000 | 2,930 | Class 10,000 | Pharma background areas, hospital pharmacy |
ISO 8 | 3,520,000 | 29,300 | Class 100,000 | Gowning rooms, oral solid dosage, packaging |
ISO 9 | 35,200,000 | 293,000 | Room air | In-operation only; general controlled areas |
Limits from ISO 14644-1:2015 Table 1; old FED-STD-209E names from Berkshire. ISO 1 and 2 are not counted at 0.5 µm. “–” means the standard does not classify at that size for that class.
The old US standard FED-STD-209E was withdrawn in 2001, but people still say “Class 100” or “Class 10,000”. Class 100 means ISO 5, Class 10,000 means ISO 7, and Class 100,000 means ISO 8.
India’s Revised Schedule M classifies sterile manufacturing clean areas into four grades, matching EU GMP. Each grade has limits for two states: at rest (equipment running, no people) and in operation (normal staffing).
Grade | What it’s used for | Particles ≥0.5 µm/m³ at rest | Particles ≥0.5 µm/m³ in operation | ISO equivalent (at rest / in operation) | Air microbes, in operation (CFU/m³) |
|---|---|---|---|---|---|
A | High-risk operations: filling, aseptic connections | 3,520 | 3,520 | ISO 5 / ISO 5 | <1 |
B | Background for Grade A in aseptic work | 3,520 | 352,000 | ISO 5 / ISO 7 | 10 |
C | Less critical sterile steps (e.g. solution preparation) | 352,000 | 3,520,000 | ISO 7 / ISO 8 | 100 |
D | Less critical steps, product not directly exposed | 3,520,000 | Not defined | ISO 8 / – | 200 |
Particle limits from Revised Schedule M, Part II, Table 1; microbial limits are the recommended averages in the same notification, given for information. ISO equivalents follow from matching the 0.5 µm limits to ISO 14644-1.
The key point for cleaning: Grade B and C rooms are allowed to get dirtier when people are working in them, which is why cleaning, gowning and staff discipline matter most during operation.
The stricter the grade, the more often you clean, the cleaner your agents and tools must be, and the more the cleaners must wear. Garment rules below come from Schedule M Part II, para 7.8; frequencies reflect typical practice and should follow your own validated SOPs.
| Grade A / ISO 5 | Grade B / ISO 5–7 | Grade C / ISO 7–8 | Grade D / ISO 8 |
|---|---|---|---|---|
Typical cleaning frequency | Before and after each session, and between batches | Every shift; walls weekly | Daily; walls and ceilings weekly to monthly | Daily floors; walls and ceilings monthly |
Disinfectants | Sterile agents only; rotate with a sporicide | Sterile agents only; rotate with a sporicide | Rotation of two or more agents plus a periodic sporicide | Rotation plus a periodic sporicide |
Cleaner’s clothing (Schedule M) | Full headgear, one-piece suit, face mask, sterile powder-free gloves, sterilised footwear | Same as Grade A | One-piece jumpsuit with high neck and wrist gathers, shoes or overshoes | Hair and beard covered, protective clothing, suitable shoes or overshoes |
Tools | Sterile, single-use or autoclaved wipes and mops | Sterile wipes, dedicated mop systems | Grade-dedicated, colour-coded mops and buckets | Grade-dedicated, colour-coded tools |
Method | Unidirectional strokes, top to bottom, clean to dirty | Same, with overlapping strokes | Two- or three-bucket mopping, top to bottom | Two-bucket mopping, top to bottom |
Schedule M also requires disinfectants to be monitored for microbial contamination, and those used in Grade A and B to be sterile before use (Part II, para 3.2).
Industry | Typical classes | Examples in India |
|---|---|---|
Sterile pharma (injectables, eye drops) | Grade A–D (ISO 5–8) | Formulation plants in Hyderabad, Goa, Ahmedabad and Baddi |
Oral solid dosage (tablets, capsules) | Grade D / ISO 8 and controlled areas | Most generic drug plants |
Biotech and biologics | Grade A–C (ISO 5–7) | Bengaluru and Genome Valley, Hyderabad |
Semiconductors and electronics | ISO 3–7 | New fabs and assembly units in Karnataka, Telangana and Gujarat |
Medical devices | ISO 7–8 | Device makers needing sterile packaging |
Hospital pharmacy and IVF labs | ISO 5–7 | Compounding rooms and IVF labs |
Food, flavours and nutraceuticals | ISO 8 and controlled areas | High-care packing zones |
Space and defence | ISO 5–8 | Satellite and instrument assembly |
PinkClean is a member of the Contamination Control Society of India (CCSI) and an ISO-certified cleaning company for pharma, biotech, electronics and industrial facilities in Bangalore, Hyderabad, Goa and Kochi.
Our clean room cleaning teams match the method to the grade:
Our industrial projects include ISRO SHAR, RenewSys, Prova Flavours and MANN+HUMMEL. For the full compliance picture, read our Revised Schedule M cleaning checklist.
An ISO 5 cleanroom allows no more than 3,520 particles of 0.5 µm or larger per cubic metre of air. It is the old “Class 100” and matches pharma Grade A.
ISO 7 allows up to 352,000 particles ≥0.5 µm per m³, while ISO 8 allows up to 3,520,000, ten times more. ISO 7 was called Class 10,000 and ISO 8 was called Class 100,000.
Class 100 is the old FED-STD-209E name for an ISO 5 cleanroom: at most 100 particles ≥0.5 µm per cubic foot, or 3,520 per cubic metre.
They are the pharma cleanroom grades in India’s Schedule M and EU GMP. Grade A is for high-risk work like filling, Grade B is its background, and Grades C and D are for less critical steps.
Yes. Grade A must meet ISO 5 particle limits both at rest and in operation. Grade B meets ISO 5 at rest but only ISO 7 in operation.
It depends on the grade and your validated SOPs. Grade A and B areas are typically cleaned every session or shift, Grade C and D daily, with walls and ceilings weekly to monthly and a periodic sporicidal round.
Schedule M requires more than one type of disinfectant in sterile clean areas, including a sporicidal agent, and disinfectants used in Grade A and B must be sterile.
PinkClean, a CCSI member and ISO-certified company, cleans Grade A–D and ISO 5–8 cleanrooms for pharma, biotech and electronics plants in Bangalore, Hyderabad, Goa and Kochi. Book a free site assessment and we’ll map a cleaning plan to each room’s grade.
📞 Bangalore: 96065 10235 · Mangalore: 91084 44692 · 🌐 pinkcleanindia.com